Enerco HSBF20LPT User Manual

Browse online or download User Manual for Accessories for electrical Enerco HSBF20LPT. Enerco HSBF20LPT User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 24
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Installation instructions and Owner’s Manual
1
UNVENTED LP-GAS FIRED ROOM HEATER
Blue Flame Heaters Plaque Heaters
Model # Burn Rate Model # Burn Rate
MHBF10LP/HSBF10LP/TSBF10LP 10,000 Btu/hr MHIR10LP/HSIR10LP/TSIR10LP 10,000 Btu/hr
MHBF20LPT/
HSBF20LPT/TSBF20LPT 20,000 Btu/hr MHIR20LP/HSIR20LPT/TSIR20LPT 20,000 Btu/hr
MHBF30LPT/
HSBF30LPT/TSBF30LPT 30,000 Btu/hr MHIRLPT/HSIR30LPT/TSIR30LPT 30,000 Btu/hr
MHIR10LP/
HS
IR10LP/
TSIR10L
P
ENERCO GROUP, INC., 4560 W. 160
TH
ST., CLEVELAND, OHIO 44135 · 216-916-3000
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing
property damage, personal injury, or loss of life.
- Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
- WHAT TO DO IF YOU SMELL GAS
Shut off gas supply
• Do not try to light any appliance
Do not touch an electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
- Installation and service must be performed by a qualified installer, service agency, or the gas supplier.
WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provi-
sions for adequate combustion and ventilation air must be provided. Refer to Fresh Air for Combustion and Ventila-
tion section on page 3 of this manual.
WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property
damage. Refer to this manual for correct installation and operational procedures. For assistance or additional
information consult a qualified installer, service agency, or gas supplier.
MHIR20LPT/
HSIR20LPT
/
TSIR20LP
T
MHBF30LPT/
HSB
F30LPT/
TS
BF30LPT
MHBF10LP/
HSBF10LP
/
TS
BF10LP
MHIR30LPT/
HSIR30LPT
/
TSIR30LP
T
MHBF20LPT/
HSB
F20LPT/
TS
BF20LPT
70575 Rev. E 04/07
INSTALLATION INSTRUCTIONS
AND
OWNER’S MANUAL
READ INSTRUCTIONS CAREFULLY: Read and follow all instructions. Place instruc-
tions
in a safe place for future reference. Do not allow anyone who has not read
these
instructions to assemble, light, adjust or operate the heater.
Installer: Leave this manual with the appliance. Consumer: Retain this manual for future reference.
Serial Number Info on Pg 24
Page view 0
1 2 3 4 5 6 ... 23 24

Summary of Contents

Page 1 - OWNER’S MANUAL

Installation instructions and Owner’s Manual1UNVENTED LP-GAS FIRED ROOM HEATERBlue Flame Heaters Plaque HeatersModel # Burn Rate Model # Burn RateMHB

Page 2 - Propane/LP Gas:

10 Installation instructions and Owner’s Manual70575 Rev. E 04/07C. Use only your hand to push in or turn the gascontrol knob. Never use tools. I

Page 3 - LOCAL CODES

Installation instructions and Owner’s Manual11TO TURN OFF GAS TO APPLIANCESHUTTING OFF HEATER:1. Turn control knob clockwise to the OFF position.2. Tu

Page 4 - Figure 2

12 Installation instructions and Owner’s Manual70575 Rev. E 04/078. When the pilot is lit, turn control knob counter-clockwise to heating level. Th

Page 5

Installation instructions and Owner’s Manual13 Figure 24aFigure 24bCLEANING AND MAINTENANCEWARNING: Turn off heater and let cool beforeservicing.CAUTI

Page 6 - Adjoining Wall

14 Installation instructions and Owner’s Manual70575 Rev. E 04/07TROUBLESHOOTINGNOTE: All troubleshooting items are listed in order of operation an

Page 7 - Mounting Bracket

Installation instructions and Owner’s Manual15TROUBLESHOOTINGWARNING: If you smell gas:• Shut off gas supply• Do not try to light any appliance• Do no

Page 8

16 Installation instructions and Owner’s Manual70575 Rev. E 04/07SPECIFICATIONSIR10 LP IR20LPT IR30LPTBTU (Available) 10,000 20,000 30,000Type of G

Page 9 - Shutoff Valve

Installation instructions and Owner’s Manual17REPLACEMENT PARTSNote: use only original replacement parts. This will protect your warranty coverage fo

Page 10 - Figure 17

18 Installation instructions and Owner’s Manual70575 Rev. E 04/07Thermostat models220-236393835162120-116-116-233-2682630291734243-522-331-131-1191

Page 11 - WHAT TO DO IF YOU SMELL GAS

Installation instructions and Owner’s Manual19IR20LPT BF20LPT IR30LPT BF30LPT1 70600 70600 70605 70605 Cabinet Assembly 11-1 70601 70601 70606 70606 C

Page 12 - 70575 Rev. E 04/07

2 Installation instructions and Owner’s Manual70575 Rev. E 04/07This appliance may be installed in an aftermarket* permanently manufactured (mobile

Page 13

20 Installation instructions and Owner’s Manual70575 Rev. E 04/07** Not sold separately – Must purchase Assembly* Items not shown29 70683 70683 706

Page 14 - TROUBLESHOOTING

Installation instructions and Owner’s Manual21NON-Thermostat models33-122-11-13-13-33-23-63-526782324131-41-21-36151442522-322-220-216-216-116220-1BF1

Page 15 - TROUBLESHOOTING CON’T

22 Installation instructions and Owner’s Manual70575 Rev. E 04/07PARTS LISTNon-Thermostat modelIR10LP, BF10LP, IR10 LP, BF10LPThis list contains re

Page 16 - SPECIFICATIONS

Installation instructions and Owner’s Manual2336 70336 --- Bracket, Bottom, Plenum Assembly 138 70677 --- Burner Plaques, 10 240 70678 --- Plaque Gask

Page 17

24 Installation instructions and Owner’s Manual70575 Rev. E 04/07WARRANTY INFORMATIONKeep this warrantyModel _______________________Serial No. ____

Page 18 - Thermostat models

Installation instructions and Owner’s Manual3Product FeaturesFigure 1SAFETY DEVICEThis heater has a pilot with an Oxygen Depletion Sensor(ODS) safety

Page 19 - PARTS LIST

4 Installation instructions and Owner’s Manual70575 Rev. E 04/07installed in that space, and an unconfined space as aspace whose volume is not less

Page 20 - DESCRIPTION QTY.ITEM

Installation instructions and Owner’s Manual5Figure 3.Ventilation from OutdoorsIf necessary, provide extra fresh air by using ventilationgrilles or du

Page 21 - NON-Thermostat models

6 Installation instructions and Owner’s Manual70575 Rev. E 04/07Figure 4FASTENING HEATER TO WALLMounting BracketThe mounting bracket in located on

Page 22

Installation instructions and Owner’s Manual71. Drill holes at marked locations using 5/16” drillbit. For solid walls (concrete or masonry), drillat

Page 23 - IR10LP BF10LP

8 Installation instructions and Owner’s Manual70575 Rev. E 04/07WARNING: This appliance requires a 3/8” NPT(National Pipe Thread) inlet connection

Page 24 - WARRANTY INFORMATION

Installation instructions and Owner’s Manual9Pressure Testing Heater Gas Connections:1. Make sure that the heater supply piping systemis connected and

Comments to this Manuals

No comments